Standard type Prefabricated House Specifications
(Cemented Chipboard + Polystyrene Hard Foam + Cemented Chipboard)
Technical Datas:
Designed against 100 km/hr wind speed, 80kg/m2 snow load, and first degree seismic zone.
Exterior and Interior Walls:
The wall panels are 10 cm-16cm thickness. There is 80mm thickness. 16 kg/m3 density B 1 class inflammable polyestern insulation board between two of 8 mm thickness Cemented Chipboards.
Wall Connection:
All the materials used in wall connections are galvanised steel sheets. Plasticcovering is used on the external side of the exterior wall. Connection steel profiles to stop condensation.
Windows:
PVC made, lead-free, and windows which suited to prefabricated house appearance are used. Windows have 4+11+4 double glazing.
Framework:
The system consists of steel components and wall panels. All of the carrier systems are specially shaped galvanised steel in the roll form machine, screw are used at junction points. Since welding is not used, it can be disassembled and reassembled at a different place if desired.
Ceiling Covering:
12mm thickness plaster plaster boards are used to cover the ceiling.
Paint:
Exterior and Interior Walls are applied with brand paint, which the color was chosen color by the customer. (Exterior Walls – acrylic and interior walls-water based plastic)
Wall Connection surfaces are filled with filler. All exterior metal surfaces are painted with double layer primary and double layer oil based sentetic paint.
Electricity installation:
Electricity cables that have TSE standards are laid inside the walls. Switches, wall outlets, and electricity fittings are fixed and tested to check the whole system works.
(Electricity board and meter are provided by buyer).
Sanitary installation:
All the materials used in Sanitary PVC pipes, wash basin, and toilet shower have TSE standards.
Mezzanine Floor (for double Story Houses):
16mm on steel floor beams (30cm Travers system) on intermediate floor pavement. It is coated with a cementitious chipboard in thickness. 80mm for sound and heat insulation between Arakat. Glasswool is used in its thickness. Carrying load is calculated as 600kg/m2.
Roof Covering:
The painted galvanised sheet is applied on 80 * 47 radius (8cm width) galvanised steel roof trusses.
Roof Isulation:
There are 80mm thickness glasswool blankets between roof covering and ceiling.
Platforms-stairs ( For Double Story Houses):
16mm on the carrier steel frame obtained from the Travers system. Ot is covered with a cementitous chipboard on thickness.
Doors:
Exterior doors are steel made, and interior doors are American style wood doors. Balcony doors are PVC made.